Product Overview

The BEC-817KG is a microcomputer-based voltage monitoring relay specifically designed for 6–35 kV substation and power plant automation systems, providing complete voltage measurement, monitoring, and control functions. The device features flexible communication interfaces and can be installed independently in power distribution equipment or integrated into relay protection panels, forming a complete automation system together with other relay protection and automation devices.

Protection Function

The device offers comprehensive voltage abnormality protection configurations, covering overvoltage protection, positive-sequence overvoltage protection, negative-sequence overvoltage protection, zero-sequence overvoltage protection, undervoltage protection, and positive-sequence undervoltage protection, meeting the requirements for voltage abnormality detection under various operating conditions. It also integrates frequency abnormality protection functions, including underfrequency islanding trip, overfrequency islanding trip, underfrequency load shedding (UFLS), and frequency-based reclosing, as well as breaker failure protection and binary input protection, ensuring reliable response of the power system during voltage and frequency abnormalities.

Control Function

The device supports local and remote control operations, meeting the requirements of unmanned and smart substations. The main control functions include local/remote open/close operations, remote setting modification, remote protection enabling/disabling, and programmable protection/signal output configuration. The device also supports CT power harvesting and split trip functions for specific application scenarios.

Application Scenario

35 kV and below substations

Power plant automation systems

Industrial enterprise power distribution systems

Distributed generation (DG) connection points

Load distribution rooms

Function

Specification

Protection Function

Overvoltage protection

Positive-sequence overvoltage protection

Negative-sequence overvoltage protection

Zero-sequence overvoltage protection

Undervoltage protection

Positive-sequence undervoltage protection

Underfrequency islanding trip

Overfrequency islanding trip

Underfrequency load shedding (UFLS)

Frequency-based reclosing

Breaker failure protection (BFP)

Non-electrical protection

Data Sampling

Voltage

13 remote digital inputs

Fault Recording

Data Recording

Protection events

Alarm events

Remote signaling

SOE events

Operation log

Control

Local/remote open and close operations

Remote setting modification

Remote protection enabling/disabling

Programmable protection/signal outputs


Top